We import your parts

Pure Steam Generators

Pure Steam Generators

The units have a number of design features to achieve an optimized function and a safe Pure Steam quality, condensed as per the latest editions of USP and EP for Water For Injection.

DESIGN FEATURES

路 Fully automatic function and surveillance.

路 Unique 4 step separation system.

路 Maximal operational safety.

路 High flexibility

路 Pure Steam quality sampling

路 Feed water degassing.

路 Space saving, easy to install

PLC AUTOMATED STANDARD FUNCTION

路 Automatic start/stop on external signal.

路 Manual start/stop.

路 Automatic pressure keeping to selected value.

路 Automatic valve regulation of heating steam, feed water and compressed air.

路 Automatic surveillance & alarms of critical process values.

EXAMPLE OF OPTIONAL EQUIPMENT

路 Feed water degassing.

路 Pure Steam sample condenser with conductivity registration.

路 Sterile air vent filter and close off.

路 Heat steam safety relief valve & pressure shut off.

路 Electro polished internal surfaces.

路 Boroscope inspection of internal welds.

路 Central control cabinet for the complete PS system.

路 Pure Steam pipe systems.

FACTORY ACCEPTANCE TESTING

路 All AQUA-NOVA PS Generators are production FAT tested at our factory before delivery. The tests are documented and the produced steam quality is verified by an independent laboratory.

路 The software is developed as per GAMP specifications. When ordered, full Pre IQ and OQ documentation will be supplied with the machines, including calibration documents.

The standard delivery documentation consists of:

路 Authorized pressure vessel drawings with material and weld certificates.

路 Mechanical component documentation and manuals.

路 Electrical and instrument documentation and manuals.

路 Machine installation, operation and service manual.